- Display of Overlapped Voltage and Current Waveform
- Maximum Demand (MD in W, KW, MW) with Programmable Period
- Harmonics Analysis ( V and I ) to the 50th Order
- Display of 25 Harmonics in One Screen with Waveform
- Display of waveform with Peak Values (512 Samples / Period), Datalogging of 32, 64, 128 or 256 Points/Cycles
- Analysis of Total Harmonics Distortion ( % THD-F )
- Graphic Phasor Diagram
- Programmable PT (1 to 3000) Ratios
| - Capture 128 Transient Events ( Time + Cycles + Faults ) with Programmable Threshold(%), Can Also be Reviewed in LCD
- 50000 Records with Programmable Interval ( 1 to 6000 seconds)
- Output of Waveform, Power Parameters and 50 Harmonics at Command.
- Large Dot Matrix LCD Display with Backlight
- Optical Isolated RS-232C Interface
- Smart Datalogging to save Battery Power for Long-term Monitoring
- Built - in Calendar Clock for Data Logging
|
| |
AC Watt ( 45 ~ 65 Hz, PF 0.5 to 1, CT=1 ) |
Range | Resolution | Accuracy of Readings | 100.0 - 999.9 W | 0.1 W | 2% ± 8 dgts | 1.000 - 9.999 KW | 0.001 KW | 2% ± 8 dgts | 10.00 - 99.99 KW | 0.01 KW | 2% ± 8 dgts | 100.0 - 999.9 KW | 0.1 KW | 2% ± 8 dgts | 1000 - 9999KW | 1 KW | 2% ± 8 dgts |
|
AC Current (45~65 Hz , True RMS) |
Range | Range | Resolution | Accuracy of Readings | 30 - 300 A | 0.00 - 300 A | 0.1 A | 1 % of range ± 8 dgts | 300 - 999.9 A | 100.0 - 999.9 A | 0.1 A | 1 % of range ± 8 dgts | 1000 - 3000 A | 1000 - 3000 A | 1 A | 1 % of range ± 8 dgts |
|
Harmonics of ACA in % and Magnitude (1 to 50th order) |
Range | Resolution | Accuracy in % | Resolution | Accuracy in Magnitude | 10.0 - 300 A | 0.1 % | ±1.0% | 0.1 A | ±1.0% of range ± 0.8A | 1000 - 3000 A | 0.1 % | ±1.0% | 1 A | ±1.0% of range ± 3 A |
|
Range | Resolution | Accuracy of Readings | 0.00 - 1.00 | 0.01 | ± 1.5 % ± 8 digits |
|
Harmonics of AC Voltage in % and Magnitude (1 to 50th order) |
Range | Resolution | Accuracy in % | Resolution | Accuracy in Magnitude | 50 - 600 V | 0.1 % | ±0.5% | 0.1V | ±0.5 % ± 0.5V |
|
|
|
|
Conductor Size | 150 mm (approx.) | Battery Type | 1.5 V SUM-3 *2 | Display | 128*64 Dot Matrix | Power Consumption | 10 mA (approx.) | Auto - Power - Off | 15 minutes | LCD update rate | 2 times/sec | Dimension | 130mm(L)*80mm(W)*43mm(H), 5.1"(L)*3.1"(W)*1.7"(H) | Accessories | Test lead*1 pair, Users manual*1, Batteries 1.5V*2 | No. of Sample / Period | 512 ( V & A ), 256 (W) | Operating Temperature | -10 to 50 | Operating Humidity | < 85% RH | Storage Temperature | -20 to 60 | Storage Humidity | < 75 % RH | Weight | 450g |
|